Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Environmental Health and Toxicology ; : e2019005-2019.
Article in English | WPRIM | ID: wpr-763722

ABSTRACT

The inhalation of naphthalene used as deodorant balls in public toilets could be an important cancer risk factor. The atmospheric concentration of naphthalene in public toilets (C(in)) was estimated both by a polyurethane foam passive air sampler (PUF-PAS) deployed in nine public toilets in Seoul, Korea and by a steady-state indoor air quality model, including emission estimation using Monte-Carlo simulation. Based on the estimated C(in), cancer risk was also assessed for cleaning workers and the general population. The steady-state C(in) estimated using the estimated emission rate, which assumed that air exchange was the only process by which naphthalene was removed, was much greater than the C(in) value measured using PUF-PAS in nine public toilets, implying the importance of other removal processes, such as sorption to walls and the garments of visitors, as well as decreased emission rate owing to wetting of the naphthalene ball surface. The 95 percentile values of cancer risk for workers based on the estimation by PUF-PAS was 1.6×10⁻⁶, whereas those for the general public were lower than 1×10⁻⁶. The results suggested that naphthalene deodorant balls in public toilets may be an important cancer risk factor especially for the cleaning workers.


Subject(s)
Air Pollution, Indoor , Clothing , Deodorants , Inhalation Exposure , Inhalation , Korea , Polyurethanes , Risk Assessment , Risk Factors , Seoul
2.
Environmental Health and Toxicology ; : 2019005-2019.
Article in English | WPRIM | ID: wpr-785732

ABSTRACT

The inhalation of naphthalene used as deodorant balls in public toilets could be an important cancer risk factor. The atmospheric concentration of naphthalene in public toilets (C(in)) was estimated both by a polyurethane foam passive air sampler (PUF-PAS) deployed in nine public toilets in Seoul, Korea and by a steady-state indoor air quality model, including emission estimation using Monte-Carlo simulation. Based on the estimated C(in), cancer risk was also assessed for cleaning workers and the general population. The steady-state C(in) estimated using the estimated emission rate, which assumed that air exchange was the only process by which naphthalene was removed, was much greater than the C(in) value measured using PUF-PAS in nine public toilets, implying the importance of other removal processes, such as sorption to walls and the garments of visitors, as well as decreased emission rate owing to wetting of the naphthalene ball surface. The 95 percentile values of cancer risk for workers based on the estimation by PUF-PAS was 1.6×10⁻⁶, whereas those for the general public were lower than 1×10⁻⁶. The results suggested that naphthalene deodorant balls in public toilets may be an important cancer risk factor especially for the cleaning workers.


Subject(s)
Air Pollution, Indoor , Clothing , Deodorants , Inhalation Exposure , Inhalation , Korea , Polyurethanes , Risk Assessment , Risk Factors , Seoul
SELECTION OF CITATIONS
SEARCH DETAIL